1-channel tabletop apparatus for 1/3 Mhz ultrasound therapy.

1 output Ultrasound therapy equipment with 1-3 Mhz frequency, adjustable power from 0.1 to 3W per cm² in pulsed mode and from 0.1 to 2W per cm² in continuous mode.

Color graphic display 320x240 pixels with Touch & Scroll function, 63 memorized programs with internal memory with more than 200 programs to memorize and smart card.

Strengths

- 1/3 Mhz multi-frequency handpiece, waterproof for underwater treatments

- Possibility of connecting it with the electrotherapy models THERAPIC 7200/9200/9400 for combined applications

- Color graphic display with Touch & Scroll functions

- Self-calibrating handpieces with their own internal emission frequencies

- Smart Card

Basic endowment:

- User manual on DVD

- Handle 1/3 Mhz of 5 cm2

- Smart Card

Ultrasound: Ultrasound therapy

Ultrasounds are high frequency acoustic vibrations not perceptible by the human ear.

In the therapeutic field , the application of ultrasound in human tissues results in a high-frequency cellular and intercellular massage action. Furthermore, ultrasound can be used in immersion; the head is immersed in water next to the area to be treated.

The tissues irradiated with ultrasound in turn enter into vibration, with consequent energy expenditure and heat production. These manifestations are summarized in the biological effects of ultrasound, mechanical effect and diathermic effect:

- The Mechanical Effect : It is developed through the rhythmic compression and decompression of tissues. The particles of a tissue subjected to the vibrating area are all alternately stressed with the same acceleration and speed.

- The Diathermic Mechanism: Hypotizable biological effects begin to be possible with an energy of 1 watt / cm2. As sound travels through tissues it is absorbed and converted into heat. The temperature distribution produced by ultrasound in tissues is unique among all forms of deep heating, this effectively determines a relatively small temperature rise on the surface of
tissues and has a greater probability of penetration into the musculature and soft tissues compared to diathermy produced with microwaves or short waves.

- Chemical Effect : Linked to a characteristic phenomenon induced by ultrasound, "cavitation", which is explained by the liquid components of the tissues where the small gaseous bubbles present tend to increase in size, and results in oxidation and polymerization processes. , destruction of macromolecules, etc.


Attached files

 

Spare parts and accessories for this product

  • TV1 1/3 MHz ultrasound handpiece emitting area of ??1 cm2
  • TV1 1/3 MHz ultrasound handpiece emitting area of ??1 cm2 Reference: ACC943/1
  •  550,55 €
  • Add to Basket
  •  
  • Shipping in 7-10 days approx.
  • TV3 1/3 MHz ultrasound handpiece emitting area 3 cm2
  • TV3 1/3 MHz ultrasound handpiece emitting area 3 cm2 Reference: ACC943/3
  •  597,70 €
  • Add to Basket
  •  
  • Shipping in 7-10 days approx.
  • 1/3 MHz ultrasound handpiece TV8 emitting area 8 cm2
  • 1/3 MHz ultrasound handpiece TV8 emitting area 8 cm2 Reference: ACC943/8
  •  639,20 €
  • Add to Basket
  •  
  • Shipping in 7-10 days approx.