Radio-Frequency Diathermy ATR Med: Adaptive Bi-Active Dynamic Diathermy Technology

Radio-Frequency Diathermy ATR Med: Adaptive Bi-Active Dynamic Diathermy Technology  
  • Radio-Frequency Diathermy ATR Med: Adaptive Bi-Active Dynamic Diathermy Technology
  • Radio-Frequency Diathermy ATR Med: Adaptive Bi-Active Dynamic Diathermy Technology
  • Radio-Frequency Diathermy ATR Med: Adaptive Bi-Active Dynamic Diathermy Technology
  • Radio-Frequency Diathermy ATR Med: Adaptive Bi-Active Dynamic Diathermy Technology

Description

Diathermy ATR Med by radio-frequency: The capacitive and resistive transfer that automatically adapts the treatment parameters to the pathological conditions of the tissues, allowing the physiotherapist a therapy centered on the patient.

Adaptive Bi-Active Dynamic Diathermy

ATR Med is a Diathermy studied, designed and developed to treat painful and traumatic pathologies of the skeletal muscles . ATR Med uses the interaction between radio frequencies and biological tissue in an innovative way .

The biological mechanisms of the cells are stimulated allowing a powerful increase of the natural process of tissue repair and an intense and immediate anti-inflammatory action.

Fluctuating high frequency (RF) waveforms , with a specific range of wavelengths, propagate positively in the organism to the deepest structures (bones, muscles, internal organs).

The presence of specific frequencies in ATR Med Diathermy allows an immediate and positive interaction with the tissues, allowing the rapid restoration of our corporal performance.

The ATR Med method stimulates the tissues from the inside acting in the deeper layers, resolving the pain and its causes , reducing the therapeutic times and accelerating the functional recovery of the tissues.

Main Actions

- Analgesia : activity of radio frequency on nerve endings.

- Drainage : it is obtained thanks to the endogenous heat developed with the radio frequency that stimulates the local blood and lymphatic circle.

- Bio-stimulation : obtained by the capacitive and resistive method at low energy levels.

- Rehabilitation, sports medicine and aesthetic medicine (lifting, cellulite, facial rejuvenation, dehydration of the skin, muscular hypotonia, etc)

Fields of application

The main operational functioning of ATR Med can be attributed to the traumatic pathologies of the skeletal muscle Even if it also includes the following fields of application:

- Physiotherapy

- Rehabilitation

• pain therapy

• sports medicine

• aesthetic medicine

- Dermatology

- Phlebology

Action mechanisms

ATR Med shows important technological innovations that make it a reliable, efficient and very powerful tool .

The exclusive features of ATR Med are:

- Automatic Control of the Energy Supplied

ATR Med is equipped with a system to control the energy delivered to the tissues during treatment . It is capable of solving the most adequate energy energy on the basis of: variations of tissue impedance; Conductive used during the treatment; Size of the electrodes; Preselected parameters at the beginning of the treatment; Capacitive or resistive.

- Efficiency of the Transfer and Calculation of Energy Absorption

ATR Med is the only device with a patented system that allows you to monitor the efficiency of energy transfer during the treatment session . This information is essential because it represents the specific power or rather the normalized power according to the volume of the treatment area. It means being sure to carry out an effective therapy with respect to the benefit attainable in a specific pathology, considering possible overloads, losses or tissue addiction.

- Interpretation of Impedance Variations

Impedance, simply, is the measure of a body's ability to pass through electrical current: a low impedance usually suggests good electrical conductivity, a high impedance means a greater electrical resistance of the tissue.

- ATR Med is equipped with an exclusive and patented biofeedback impedenziometric system to evaluate the efficiency of energy transfer to tissues in real time.

This innovation allows to energize the tissues in a selective and efficient way through a diagnostic evaluation of the skin's susceptibility and to adequately modulate the parameters of use of the machine according to an evaluation of the state of progress of the therapy in terms of efficacy therapeutic and response to the harm solution.

With ATR Med, the impedance variations are monitored and displayed in real time in each phase of the treatment . This allows the operator to verify immediately, not only the initial state of the tissue, but the entire settling process during the therapy cycle.

Method with Electrodes Dynamic Bi-Active

Dynamic bi-active electrodes are unique to ATR Med and allow a particular treatment. Maneuvers without using the fixed neutral. (Necessary purchase of an optional accessory)

Advantage:

- Possibility of focusing or spreading the energy simply by changing the movements of the electrode;

- Possibility to modulate the power simply using the actions of the electrode;

- Bipolar function

Double neutral method

With ATR Med an additional evolution is represented by the double neutral plate method that allows obtaining:

- Energy balance or rather a symmetric supply of radio frequencies, very useful if specific areas of the body are treated, such as the back

- Expansion of the energizing area, considerably reducing the treatment time if wide areas of the body are covered.

- Uniformity of energization allowing to maintain even the energy supplied to the tissues including areas far from neutrality.

Technical characteristics

Technical data

- Frequency of emissions: from 215hz to 645khz

- Output power 100 ohm (not isolated): 450w ac

- Max. Input power: 600w

- Output voltage resistive electrode: max 150v rms

- Capacitive output voltage electrode: maximum 1200v rms

- Capacitive electrode capacity: 200 - 2000pf

- Medical class equipment: ii b

- Characteristic cables: 4kv insulation with screens

Multi-Frequencies

ATR Med is capable of generating different frequencies to improve the effects of therapy . Each essential frequency is indicated by a work program:

- NRV, where the basic frequency is 215 KHz, leads to a powerful analgesic and anti-inflammatory effect;

- PLUS, where the harmonic frequency is 430 KHz, the effects are predominant in the deep structures of the skeletal muscle.

- EVOLUTION, where the harmonic frequency is 645 KHz, the effects are particularly suitable for more superficial skeletal muscle structures;

Electrodes

The construction characteristics of the electrodes used with ATR Med are patented.

- Aluminum / Resistor: Aluminum is a strong acceptor and binds very easily to the ions present in the fabric allowing a better. Performance than the most common stainless steel.

- Isolated / capacitive bycorundum : Corundum has a higher dielectric coefficient than materials such as Teflon, pvc or ceramic glass. Coefficient is so high that a 150 micron layer of corundum is sufficient to obtain a greater than one 1000 micron layer of other materials. Electrical connection, with capacities even 100 times higher than standard electrodes with thickness.

 

Spare parts and accessories for this product

  • Diathermy Capacitive and Resistive Book. Excellence in electrotherapy
  • Diathermy Capacitive and Resistive Book. Excellence in electrotherapy Reference: 84-617-5796-1
  •  70,00 €
  • Add to Basket
  • Product in stock. Immediate shipping