Dino-Lite CapillaryScope 200 Pro Digital Capillaroscope: with 1.3 MP camera, 50x and 200x magnification, and polarized light
* The shipping costs are calculated in the shopping basket
Reference: MEDL4N Pro
Description
He Dino-Lite CapillaryScope 200 Pro digital capillaroscope It is a medical examination device designed to facilitate the magnified observation of blood capillaries and study of microcirculation, especially by means of periungual capillaroscopy.
This Professional capillaroscope for rheumatology It incorporates a digital camera 1.3 megapixels (1280 × 1024 pixels), increases of 50x and 200x and a lighting system using 8 white LEDs with linear polarizerwhich helps reduce surface reflections and enhances the visualization of hair structures.
The Dino-Lite MEDL4N Pro integrates the technology AMR (Automatic Magnification Reading)which allows automatic identification of the magnification level used, facilitating the recording of this information during digital observation.
Its USB 2.0 connection and software DinoCapture 2.0 for Windows and DinoXscope for Mac They allow viewing, capturing and storing photographs and videos of the explorations, facilitating documentation and visual monitoring.
Thanks to its compact design, it weighs only 105 grams and its specific cap for capillaroscopy N3C-N CapillaryScopeIt constitutes a practical tool for consultations in rheumatology, dermatology and other medical specialties interested in the study of microcirculation.
Strengths:
- Specialized in digital capillaroscopy: designed to facilitate magnified observation of superficial capillaries, especially in the periungual region.
- 50x and 200x magnifications: It allows observation of the general arrangement of the capillaries and examination of details of their morphology with greater magnification.
- 1.3 megapixel digital camera: It offers a resolution of 1280 × 1024 pixels for image viewing and documentation.
- AMR (Automatic Magnification Reading) Technology: It automatically identifies the selected magnification and facilitates its registration in compatible software.
- Integrated linear polarizer: It helps reduce surface reflections during observation.
- Lighting by means of 8 white LEDs: It provides lighting during the scan, with the option to turn it on and off.
- N3C-N CapillaryScope Specific Cap: accessory designed for capillary observation.
- MicroTouch Sensor: It facilitates image capture through a control integrated into the device.
- Increase lock: It allows you to keep the selected settings fixed during the scan.
- Glass lens with anti-reflective coating: It helps to improve image clarity.
- DinoCapture 2.0 and DinoXcope software: It allows you to view, capture, and store images from Windows and Mac computers.
- Compact and lightweight design: Weighing 105g, it is easy to handle during examinations.
- Class I medical device: in accordance with Regulation (EU) 2017/745, according to the manufacturer's documentation.
Technical specifications:
Lightning:
- LED light type: White
- Number of LEDs: 8
- LED on/off: Yeah
- Infrared filter: IR cut filter above 650 nm
- Diffuser: Not available
- Polarizer: Yes, linear
Optics:
- Increases: 50x and 200x
- Lens type: Glass with anti-reflective coating
Sensor and image:
- Sensor type: CMOS
- Resolution: 1.3 megapixels (1280 × 1024 pixels)
- Maximum capture speed: 30 fps
Connectivity and compatibility:
- Interface: USB 2.0
- Operating systems: Windows 7, 8, 10 and 11; macOS 10.9 or later
- Included software: DinoCapture 2.0 (Windows) and DinoXcope (Mac)
- Image formats (Windows): BMP, GIF, PNG, JPG, TIF, RAS, PNM, TGA, PCX, MNG, WBMP, JP2, JPC and PGX
- Video formats (Windows): WMV, FLV and SWF
- Image formats (Mac): JPEG and PNG
- Video formats (Mac): MOV
- Image standards: DirectShow and UVC
Design and dimensions:
- Housing material: Composite material / plastic
- Increase lock: Yeah
- Dimensions: 10.5 cm long × 3.2 cm in diameter
- Weight: 105 g
- Cable length: 1.8 m
Additional features:
- AMR Technology: Yes, automatic reading of the increase
- MicroTouch Sensor: Yeah
- Measurement function: No
- Calibration function: No
Applications of the Dino-Lite CapillaryScope 200 Pro digital capillaroscope:
The Dino-Lite CapillaryScope 200 Pro is geared towards healthcare professionals who need to make magnified observations of superficial blood capillaries and document their findings using digital images.
Among its main applications are:
- Rheumatology: exploration of periungual capillaries as part of the study of microvascular alterations and connective tissue diseases.
- Periungual capillaroscopy: observation of the shape, arrangement and morphological characteristics of the capillaries of the nail fold.
- Raynaud's syndrome: support for the clinical assessment of possible microcirculatory disorders.
- Systemic sclerosis: documentation of capillaroscopic patterns as a complement to the specialist evaluation.
- Dermatology: expanded observation of certain superficial vascular structures.
- Clinical follow-up: capturing images to document and visually compare findings.
- Teaching and research: visualization of magnified capillary images for training activities and microcirculation studies.
Advantages of digital capillaroscopy with magnification up to 200x:
The Dino-Lite CapillaryScope 200 Pro capillaroscope allows combining the observation of capillaries at 50x with a magnification of 200x, facilitating the examination of different details of the superficial microcirculation.
The lighting provided by 8 white LEDs and the linear polarizer help to improve viewing conditions, while the digital camera allows images to be recorded for later review.
In addition, AMR technology automatically identifies the selected magnification, making it easier to document scans in compatible software.
Digital capillaroscopy is a non-invasive technique of interest in rheumatology and other medical specialties, especially when used as a complement to a clinical evaluation performed by qualified professionals.
Base staffing:
- Dino-Lite CapillaryScope 200 Pro digital capillaroscope
- Carrying case
- CD with manufacturer's software
- User manual
- N3C-N CapillaryScope specific cap
Warranty:
- 2-year warranty