Roland 2 Combination Therapy Equipment (ultrasound and electrotherapy)

Roland 2 Combination Therapy Equipment (ultrasound and electrotherapy)  
4.416,50€ Including VAT(3.650,00€ without VAT)
 
 

Shipping in 10-15 days approx.

* The shipping costs are calculated in the shopping basket

Reference: LOG-X5EU

Description

Description:

Electrotherapy combined team (electrotherapy of low and medium frequency ultrasound + 1/3 Mhz), with possible extension to other technologies: laser high energy density, magnetic therapy, shockwaves, and trc microwave diathermy, vacumterapia.

TECHNICAL electrotherapy:

• Outputs: n. 2

• Power consumption: 150 VA

• Dimensions: 40x40x23 cm h

• Power supply: 115-230 V - 50/60 Hz

• IEC Protection Class 1 BF

• Directive 93/42 EEC: IIb

Low Frequency

• Galvanic interrupted, diadynamicas (50-100 Hz, CP, LP, 50 Hz and 100 Hz interrupted and interrupted), rectangular, triangular, exponential biphasic, Trabert, faradic (rectangular, triangular, neodyn)

• Intensity: max. 76.5 mA (153.00 map)

Average frequency:

• Outputs: 2

• Frequency: 2.5 kHz and 4.8

• bipolar and tetrapolar

• bipolar BF, BF quadrupole, BF Isoplanar, vector BF, MF stimulation, Kotz

• Intensity: max. 76.5 mA (150 MAP)

• Display: 480x800 pixel color LCD

• Track-ball to set parameters

• Pre-established protocols with maps

• Free Memory for custom protocols (unlimited)

ULTRASOUND TECHNICAL SPECIFICATIONS:

Power consumption: 80 VA

• Power supply: 115-230 V - 50/60 Hz

• Dimensions: 40x40x23 cm h

• IEC Protection class: 1 B

• Directive 93/42 EEC: IIa

• 1-2-3 MHz multifrequency ultrasound unit

• continuous and pulsed (20 to 80%), ultrasound therapy

• Modulation: 1 to 200 Hz

• Multi head 5 cm2 1-2-3 MHz working alone or in combination

• Automatic calculation of the depth and power density

• Automatic switch off

• Timer 30 minutes

• Display: 480x800 pixel color LCD

• Track-ball

• Memories Unlimited

• Pre-set protocols with maps locations

• 3 W cm2 in continuous and pulsed modes

• real-time display device correct contact between the head and the patient

Possibility of extending the unit up to 4 additional therapies to choose between electrotherapy, laser high energy density, magnetic therapy, shockwaves, microwave diathermy and trc.

Accessories included: Cable set (black and red), a set of electrodes and sponges 60x80 mm, parde elastic straps, instruction manual, power cord, multi-head 5 cm2, gel 250 gr, instruction manual, power cord

Optional accessories:

• A pair of electrodes 50x50 mm

• Par 50x50 mm sponge

• A pair of electrodes 120x80 mm

• Pair of 120x80 mm sponge

• Set of 4 adhesive electrodes 40x40 mm

• Set of 4 adhesive electrodes 80x40 mm

• elastic strap with velcrum

• electrode Pen

• Current draw

• If the horizontal current isodynamic to 20 KHz

• High voltage module with standard accessories

• multi-frequency 1 cm2 head

• 8 cm2 static head with elastic band

• multilevel modules 1-3 MHz with 5 heads for sequential applications

• Shopping mod. Roland 2 without drawers

• Shopping mod. Roland 2 with 3 drawers