Apparatus for ultrasound table with two completely independent channels, with two multi handpieces 1/3 Mhz supplied.

 

Equipment for ultrasonic therapy frequently 2 independent outputs 1-3 Mhz, power adjustable from 0, 1 to 3W cm² in pulsed mode and 0.1 to 2W per cm² in continuous mode.

Color graphic display 320x240 pixels with Touch & Scroll function. 63 internal programs stored with m emory with more than 200 programs to save and Smart Card.

Strengths

- Two completely independent outputs for dual applications

- 1/3 MHz multifrequency handpiece, waterproof down water treatment

- Ability to connect with electrotherapy Therapic 7200/9200/9400 models for composite applications

- Graphical color display with features Touch & Scroll

- Handpieces with self-calibrators own internal broadcast frequencies

- Smart Card

Supplied accessories

- Manual on DVD

- Handpiece 1/3 Mhz of 5 cm2, 2 units

- Smart Card

Ultrasound: Ultrasound therapy

Ultrasounds are acoustic vibrations of high frequency not perceptible by the human ear.

In therapeutic field, the application of ultrasound in human tissues action results in cellular and intercellular massage high frequency also can be used in ultrasound immersion; the head is submerged in water near the area to be treated.

The tissues irradiated with ultrasonic entering turn on vibrate, with consequent energy consumption and heat production. In these manifestations are summarized in the biological effects of ultrasound, diathermy mechanical effect and effect:

- Mechanical Effect: It develops through the rhythmic compression and decompression of tissues. Particles of a tissue subjected to the vibrating area are all alternately applied with the same acceleration and speed.

- Diathermy Mechanism: Hipotizables biological effects begin to be possible power 1 watt / cm2. As the sound propagates through tissue is absorbed and converted into heat. The temperature distribution produced by ultrasound in tissue is unique among all forms of deep heating, this effectively determines a temperature increase in the relatively small surface
tissues and has a greater chance of penetration muscles and soft tissues regarding microwave diathermy produced or shortwave.

- Effect Chemical: linked to a characteristic phenomenon induced by ultrasound, "cavitation", which is explained by the liquid components of the tissues where small gas bubbles present tend to increase in size, and results in oxidation, polymerization , destruction of macromolecules, etc.


Attached files

 

Spare parts and accessories for this product

  • TV1 1/3 MHz ultrasound handpiece emitting area of ??1 cm2
  • TV1 1/3 MHz ultrasound handpiece emitting area of ??1 cm2 Reference: ACC943/1
  •  550,55 €
  • Add to Basket
  •  
  • Shipping in 7-10 days approx.
  • TV3 1/3 MHz ultrasound handpiece emitting area 3 cm2
  • TV3 1/3 MHz ultrasound handpiece emitting area 3 cm2 Reference: ACC943/3
  •  597,70 €
  • Add to Basket
  •  
  • Shipping in 7-10 days approx.
  • 1/3 MHz ultrasound handpiece TV8 emitting area 8 cm2
  • 1/3 MHz ultrasound handpiece TV8 emitting area 8 cm2 Reference: ACC943/8
  •  639,20 €
  • Add to Basket
  •  
  • Shipping in 7-10 days approx.